Non-thyroid mammalian cells, CHO-K1 cells, stably expressing human thyrotropin receptor (CHO-TSH-R cells) were used for the assay of thyroid stimulating antibody (TSAb) activities of IgGs from 24 patients with Graves' disease and we compared them with the values obtained in porcine thyroid cells. A significant positive correlation was observed between the results given by CHO-TSH-R cells (hTSAb) and porcine thyrocytes (pTSAb) (r = 0.94, p less than 0.001). However, we found that hTSAb values of IgGs from 5 patients were extremely different from their hTSAb values. Four out of these 5 IgGs showed strong pTSAb activity but exhibited a weak or negative hTSAb activity. Conversely, one out of 5 autoantibodies was very strong for hTSAb but its pTSAb was low. These heterogeneous responses of recombinant hTSH-R to Graves' IgGs suggest that there exist different types of TSAb and also that the epitope(s) for TSAb may be different from case to case.