Outcomes of complex primary total knee arthroplasties performed with custom cutting guides

Knee. 2021 Jun:30:106-112. doi: 10.1016/j.knee.2021.03.019. Epub 2021 Apr 20.

Abstract

Background: Total knee arthroplasty (TKA) is particularly challenging in patients with marked deformities or existing hardware due to the inability to use traditional instrumentation. One potential technique to mitigate this obstacle is the use of patient-specific cutting guides. The purpose of this study was to evaluate the use of custom cutting guides in complex primary TKAs.

Methods: Twenty complex TKAs performed in 18 patients were identified. Of these, 11 were performed in patients with existing hardware, three in patients with dwarfism, three in patients with post-traumatic deformities, two in a patient with multiple epiphyseal dysplasia, and one in a patient with a large deformity from Blount's disease. All prior hardware was retained. One patient died from unrelated causes three months following surgery. The remaining patients were followed for a mean of 5.2 years (range: 1.2-9.7 years).

Results: One patient sustained a non-displaced, medial tibial plateau fracture intra-operatively that was successfully treated with plating. Mean operative time was 112.1 ± 44.4 min, and mean hospital stay was 2.7 ± 1.6 days. Average deviation from the mechanical axis improved from 10.5° pre-operatively to 3.1° postoperatively (P < 0.001). Average Knee Society Scores improved from 48.1 to 77.4 points (P < 0.001). Mean extension improved from 5.9° to 1.4° (P = 0.049). Two patients subsequently required a manipulation under anesthesia, and one patient had delayed wound healing that resolved without surgery.

Conclusions: Custom cutting guides are a viable option in complex primary TKAs where the use of traditional instrumentation would be challenging.

Keywords: Complex total knee arthroplasty; Custom cutting guides; Extra-articular deformities; Patient-specific instrumentation; Retained hardware.

MeSH terms

  • Aged
  • Arthroplasty, Replacement, Knee / adverse effects
  • Arthroplasty, Replacement, Knee / instrumentation*
  • Arthroplasty, Replacement, Knee / methods*
  • Bone Malalignment / diagnostic imaging
  • Bone Malalignment / prevention & control
  • Female
  • Follow-Up Studies
  • Humans
  • Intraoperative Care / instrumentation*
  • Intraoperative Care / methods*
  • Knee Joint / diagnostic imaging
  • Knee Joint / surgery*
  • Knee Prosthesis
  • Male
  • Middle Aged
  • Operative Time
  • Tibia / diagnostic imaging
  • Tibia / surgery*
  • Treatment Outcome