Small lesion classification on abbreviated breast MRI: training can improve diagnostic performance and inter-reader agreement

Eur Radiol. 2022 Aug;32(8):5742-5751. doi: 10.1007/s00330-022-08622-9. Epub 2022 Feb 25.

Abstract

Objective: To determine whether the diagnostic performance and inter-reader agreement for small lesion classification on abbreviated breast MRI (AB-MRI) can be improved by training, and can achieve the level of full diagnostic protocol MRI (FDP-MRI).

Methods: This retrospective study enrolled 1165 breast lesions (≤ 2 cm; 409 malignant and 756 benign) from 1165 MRI examinations for reading test. Twelve radiologists were assigned into a trained group and a non-trained group. They interpreted each AB-MRI twice, which was extracted from FDP-MRI. After the first read, the trained group received a structured training for AB-MRI interpretation while the non-trained group did not. FDP-MRIs were interpreted by the trained group after the second read. BI-RADS category for each lesion was compared to the standard of reference (histopathological examination or follow-up) to calculate diagnostic accuracy. Inter-reader agreement was assessed using multirater k analysis. Diagnostic accuracy and inter-reader agreement were compared between the trained and non-trained groups, between the first and second reads, and between AB-MRI and FDP-MRI.

Results: After training, the diagnostic accuracy of AB-MRI increased from 77.6 to 84.4%, and inter-reader agreement improved from 0.410 to 0.579 (both p < 0.001), which were higher than those of the non-trained group (accuracy, 84.4% vs 78.0%; weighted k, 0.579 vs 0.461; both p < 0.001). The post-training accuracy and inter-reader agreement of AB-MRI were lower than those of FDP-MRI (accuracy, 84.4% vs 92.8%; weighted k, 0.579 vs 0.602; both p < 0.001).

Conclusions: Training can improve the diagnostic performance and inter-reader agreement for small lesion classification on AB-MRI; however, it remains inferior to those of FDP-MRI.

Key points: • Training can improve the diagnostic performance for small breast lesions on AB-MRI. • Training can reduce inter-observer variation for breast lesion classification on AB-MRI, especially among junior radiologists. • The post-training diagnostic performance and inter-reader agreement of AB-MRI remained inferior to those of FDP-MRI.

Keywords: Breast neoplasms; Diagnosis, differential; Magnetic resonance imaging; Observer variation; Training.

MeSH terms

  • Breast Neoplasms* / diagnostic imaging
  • Female
  • Humans
  • Magnetic Resonance Imaging* / methods
  • Observer Variation
  • Retrospective Studies
  • Sensitivity and Specificity